ibaBM-PN
Version history

bmpn_v01.07.002 - 2023-10-18

Improvements

  1. Sniffer module - Configuration via MAC address #23063

Bugfixes

  1. Sniffer - support DCP DeviceRole=0x03 #23707

 

bmpn_v01.07.001 - 2022-05-04

ibaPDA v7.3.13 or newer is required for using the enhanced diagnostics

New features

  1. Support of ERTEC 200P-2 #15250

Improvements

  1. PROFINET and general network diagnostics enhancement #18473

Bugfixes

  1. Sniffer LED are red after booting #18814
  2. TAP is not 100% passive in some cases #18896
  3. Outputs don't work any more #20462
  4. CPU stops when data aquisition is restarted if outputs are used #14510

New GSDML file

GSDML-V2.42-ibaBM-PN-20220201.xml

  1. supports PNIO Version V2.42 #20509

 

bmpn_v01.06.001 - 2021-03-24

ibaPDA v7.3.0 or newer is required

New features

  1. PROFINET and general network diagnostics #11315
  2. Support Online Hexviewer for sniffed data #13110

Improvements

  1. Faster startup of sniffer #16612

New GSDML file

GSDML-V2.35-ibaBM-PN-20210301.xml

  1. new subslot with 240 Byte outputs #18560
  2. new "uneven" IRT update cycles #18561

 

bmpn_v01.05.001 - 2020-04-24

New features

  1. Support of S2 system redundancy #12732

Improvements

  1. Display update time per slot #6347

 

bmpn_v01.04.002 - 2019-07-05

Bugfixes

  1. AR slot configuration for sniffing could be lost #14734
  2. No signals from IRT-Multicast-AR in some configurations #14841

 

bmpn_v01.04.001 - 2019-05-02

New features

  1. Support of SINAMICS Link configurations with a single SINAMICS CU320 #13400

 

bmpn_v01.03.004 - 2018-09-18

Bugfixes

  1. possible data corruption for sniffer data fixed #13323

 

bmpn_v01.03.003 - 2018-06-20

Bugfixes

  1. possible data corruption for input slots of device 1 fixed #12879

 

bmpn_v01.03.002 - 2018-03-16

Bugfixes

  1. Sniffer process doesn't boot on some devices #12556

 

bmpn_v01.03.001 - 2018-02-21

New features

  1. PDA outputs #6342
  2. Support of MRPD #8900

Improvements

  1. Shared device with up to 4 controllers per device #6424
  2. additional slot sizes (4, 8, 16 and 32 bytes) #11913
  3. show assigned IP address in device details #11421

 

bmpn_v01.02.002 - 2017-12-01

Bugfixes

  1. No signals from IRT-Multicast-AR after the PDA-Configuration-Apply or after a reboot. #12043 #12046 #12063

 

bmpn_v01.02.001 - 2017-09-04

New features

  1. Sniffer functionality #6344

Improvements

  1. Update of FO-Modul to v178 #11504
  2. Show state of the Monitor-Port #11542

Bugfixes

  1. Factory default with pressing S10-button, if devices connected to controller #6345
  2. Monitor port: improvements connection establishment #7753 #11119 #11399
  3. Sporadic red Led of device0 or device1 (ERTEC) after a cold start #11123

 

bmpn_v01.01.003 - 2017-06-09

Bugfixes

  1. Data corruption in case of less than 8 Byte data per slot #11043

 

bmpn_v01.01.002-rc1 - 2016-09-16

internal version

Improvements

  1. Validation of AR connect made compatible to Rexroth CML45 controller #8646

 

bmpn_v01.01.001 - 2016-04-26

First Release